Cryolab Publishes Technical Guide to Liquid Nitrogen Storage for Hatchery Vaccines

eTradeWire News/10854160
New guide from cryogenic equipment specialist Cryolab Ltd sets out how hatcheries and veterinary vaccine distributors should size, site and maintain liquid nitrogen storage for frozen poultry vaccine, where there is no refrigerated fallback.

CHICHESTER, U.K. - eTradeWire -- Cryolab Ltd, the cryogenic equipment and consumables specialist, has published a technical guide to liquid nitrogen storage for frozen poultry vaccine.

Cell-associated Marek's disease vaccine, and the HVT-vector vaccines built on it, are living cells and are stored and transported in liquid nitrogen at -196 degrees C from manufacture to the point of use. There is no refrigerated fallback. The product instructions state that an ampoule which thaws by accident must be discarded and must not be refrozen under any circumstances, which makes the nitrogen level check the single control the whole cold chain rests on.

More on eTradeWire News
The guide addresses the questions hatchery managers and veterinary vaccine distributors raise most often. It sets out why vessel selection should start from the number of canes held and the retrieval time rather than from litres, given that the concentrate is supplied in 2 ml type I glass ampoules mounted on canes and commonly holding 500, 1,000, 2,000 or 4,000 doses. It covers sizing to peak inventory held immediately after a delivery rather than to the average, and the role of static holding time as margin against a missed fill or a late nitrogen delivery.

On siting, the guide notes the instruction that containers stand upright in a clean, dry, well ventilated room separate from the hatching or chicken room, and the two-hour window within which the vaccine must be used once reconstituted, kept below 25 degrees C, which makes the distance from the vessel to the injection point part of the specification.

More on eTradeWire News
It also covers room safety. One litre of liquid nitrogen becomes roughly 683 litres of gas at 1.013 bar and 15 degrees C, so workplace oxygen should be held above 19.5 per cent with monitoring and an audible alarm, and room volume checked against the quantity stored. On operator safety the guide highlights a hazard that is often overlooked: frozen glass ampoules can burst during sudden temperature changes, which is why the instructions require gloves, eye protection and boots for handling, withdrawing, thawing and opening.

Cryolab was established in 2000, holds ISO 9001:2015 certification and supplies cryogenic equipment, consumables, accessories and servicing to healthcare, fertility, research and animal health users internationally, with standard UK stock items typically delivered next day.