Cryolab Publishes Guide to Cryogenic Labels and Sample Identification at -196 Degrees Celsius

eTradeWire News/10853562
New guidance from the cryogenic equipment supplier sets out identification as four layers rather than one label, and explains why most label failures in cryogenic storage are application failures.

WEST SUSSEX, U.K. - eTradeWire -- Cryolab was established in 2000 and supplies cryogenic equipment, consumables, accessories and servicing to healthcare, fertility and research organisations in the UK and internationally. The company holds ISO 9001:2015 certification and is the exclusive UK and Ireland distributor for CryoBioSystems.

The guide is also direct about why labels come off. Most failures are application failures rather than product failures. The surface was damp or frosted, the pressure was too light, or the vial went straight back into the cold before the adhesive had time to bond. Apply warm, apply dry, press firmly and allow time at room temperature.

More on eTradeWire News
The fourth layer is the inventory record, which answers where the sample should be and who moved it. Three fields per position are recommended: identifier, date in, and date and reason out. The guide notes that the third is the field most often dropped and the one an inspection asks for.

The third layer is the box or canister, which answers where in the vessel the sample sits. Cryolab advises labelling the end face that stays visible while the box is racked rather than the lid, because lids are swapped and a swapped lid mislabels two boxes at once.

The second layer is the cane, visotube or goblet, which answers which group the sample belongs to. It is read with gloves on, over the open neck of a vessel, so colour works faster than text. Coders, identification tabs and identification rods exist for this. The guide warns that a colour scheme is only as good as the written key behind it, and a scheme held in one person's head becomes a liability within a couple of years.

More on eTradeWire News
The guide makes a point that is often missed in laboratory practice: identification is not one label, it is four layers, and a store is only as reliable as its weakest one.

The first layer is the vial or straw, which answers which sample this is. It is the smallest surface in the chain, carries the most frost and is handled more than anything else, so it needs a printed cryogenic label or a marking in cryogenic ink rather than an ordinary laboratory pen.

The full guide is available at https://cryolab.co.uk/cryogenic-labels-and-sample-identification-what-stays-readable-at-196-degrees-c/

Cryolab Ltd has published a practical guide to cryogenic labels and sample identification, aimed at the IVF clinics, biobanks, blood and tissue services and research laboratories that store material at temperatures down to -196 degrees Celsius.